Gamry EIS300 EIS Software Includes Experimental scripts for potentiostatic. On the analysis side, it provides tools for fitting spectra to equivalent circuit models. • Electrochemical Impedance Spectroscopy (EIS) steady state relaxation dynamic relaxation transient perturbation of equilibrium state Next slide. EIS & Nano-El-Cat. The ac impedance measurement technique discussed in the product note entitled Making Fuel Cell ac Impedance Measurements Utilizing Keysight N3300A Series Electronic Loads is used in this EIS software developed specifically for Keysight instrumentation. Use the equipment set-up shown in the product note. The software consists of an Excel spreadsheet running a Visual Basic program that is used to program the electronic load and function generator through a GP-IB card, make measurements using the built-in readback of the load, calculate the ac impedance from the measurements, and display the results on the computer screen. Drivers for the N3300A load, 33120A, and/or 33220A function generators are required and can also be downloaded from Keysight for free. The Analysis ToolPak (from Tools/Add-Ins) must also be loaded from within Excel for the program to function properly. Bonjour John, * The Khi2 definition is given in the ZfitGUI manual:. Dowload the manual, then open it with Word to read it properly (some formulae may disappear with other viewers; I will correct that soon). * Fval from Zfit is the same: fval=Khi2, but only if the weigthing method is left as default: proportionnal. Otherwise, Fval is the value of the minimized function (which is the difference Ztheo versus Zexp) at the solution as stated in the fminsearch Matlab definition. Once again, some details which can help are given in the ZfitGUI manual. Best regards, Jean-Luc. Bonjour Jacopo, I just have received today the notification of your coments. To answer your first coment, I think it could come from the starting values which must close the best ones when using CPE. Another hint is to try the 'fitNP' string (fit Not Proportionnal). I mean a fit could appear badly completed when estimated by eyes on the Z spectrum when it is good when checking the sum (error(i)/Z(i)) given by the output parameter fval. About your second and interressing coment, I would like to get the data and the modified code. ![]() In order to check by myself. Durga saptashati path hindi mp3 free download. First of all, thanks for this program, it's gonna really help me. Second: I think that I managed to improve your function so now p() and s() can work with any number of parameters (maybe not 0, but a check is easy to implement); Third I have a question for you: I tried to fit a complex circuit: s(R1,s(p(E2,R1),p(E2,R1))) with some data, but I'he got a fit that was worste then the input parameters (obtained via EIS software analyzer and entered in your program with 3 significant digit). Any idea why? 1/ I tried your string and there was no error. I think the limit in the amount of elements is higher. So there is no problem to simulate data. 2/ Fitting experimental data with long strings will be an other task and you would beware of overparametrization (too many elements) leading to some parameter to have nonsensed values. 3/ I tried your string on some data and get the minimizer failed at the first try. As said in the help, I retried with the returned 'pbest' as initial parameters and get the convergence. To end, I prompt you to use the 'ZfitGUI' function which eases the data weigthing. Best regards.
0 Comments
Leave a Reply. |